HomePhabricator
Diffusion MITK 61c29856fd9a

The concentration curve converter view is updated to have all the…

Description

The concentration curve converter view is updated to have all the functionalities of the concentration converter in the MR perfusion view. Additionally, the following tasks are fixed: T27671, T27667, T27666, T27654.

Summary:
Update CreateQTPartControl to handle box visibilities.

Remove option "no conversion".

Update CheckSettings

Add boost math constants.

spinBox_baselineEnd/StartTimeStep settings

Enable factorSpinBox as default.

Change due to removal of noConversion option.

ConcentrationGen updates.

Add missing BaselineStartTime/EndTimeStep input. Add NodePredicates.

New selection widget for time series, 3D image and baseline image selection.

Use new selection widget concept for T2-weighted times series.

Correct T2-conversion formula as described in T27667.

Remove autoselect, otherwise images get chosen before settings are set.

Add baseline averaging functionality to T2 conversion.

Correct T2 conversion conversion formula.

Use modelFitResultRelationRules to define isNoModelFitNodePredicate.

Remove commented out/unnecessary code.

Correct typo.

Add unit ms to echo time TE label as described in T27666.

Change size policy of groupBox_T2 to improve UI appearance.

Only enable T2 conversion button, when baseline selection settings are ok.

Test Plan: Manual

Reviewers: floca, O3 MITK Reviewer Group II

Reviewed By: floca, O3 MITK Reviewer Group II

Differential Revision: https://phabricator.mitk.org/D401

Details

Provenance
kompanAuthored on Sep 28 2020, 1:31 PM
kompanPushed on Sep 28 2020, 3:27 PM
Reviewer
O3: MITK Reviewer Group II
Differential Revision
Restricted Differential Revision
Parents
rMITK6d502dec2546: Set Convert to concentration button enabled after data and settings are checked.
rMITK21448a29e41d: Revise Segmentation Utilities Plugin Documentation
Branches
Unknown
Tags
Unknown

Merged Changes