Page MenuHomePhabricator

[3D Segmentation] UL Threshold Tool - 0 intensity value not include in slider range?
Open, NormalPublic

Description

ul-threshold-0val.png (235×1 px, 47 KB)

From the checklist: BUG: When the lowest image intensity is 0, there is no way to select the value 0 as part of the segmentation because when the slider is set to 0, 0 is not included (probably > and not >=)

I can't image a used case for this.

Event Timeline

s349i renamed this task from [Segmentation] UL Threshold Tool - 0 intensity value not include in slider range? to [3D Segmentation] UL Threshold Tool - 0 intensity value not include in slider range?.Mar 30 2022, 4:17 PM
kislinsk triaged this task as Normal priority.Apr 1 2022, 9:32 AM

I am not able to reproduce this problem on Windows 10 using brain.nrrd as test image

I just had another look at this. I was able to reproduce the bug this time. It seems that this problem only arises if the image holds floating point values, not when all values are integers.

floca added a project: Restricted Project.Oct 11 2023, 11:55 AM