User Details
- User Since
- Aug 1 2016, 12:10 PM (441 w, 2 h)
- Roles
- Disabled
Aug 2 2016
I've reproduced the bug.
The problem is that on switching to the datamanager, the measurement is still selected in the render window, but the measurement value disappears.
After switching to the datamanager, the same measurement can't be selected again.
[a3183d]: Merge branch 'bug-16600-UnselectingMeasurementByClickingOnDatamanager'
Merged commits:
2014-01-29 16:36:00 Silvio Kolb [91b8a0]
Changed iteration over all datanodes and casting
them to iteration over a subset of datanodes that are planarfigures
New remote branch pushed: bug-16600-UnselectingMeasurementByClickingOnDatamanager
[60cc7f]: Merge branch 'bug-16470-WrongFileExtensionsForAllPlattforms'
Merged commits:
2014-02-19 15:35:42 Silvio Kolb [9ef651]
fixed plattform dependency.
added QDirectories.
New remote branch pushed: bug-15377-VolumerenderingGuiIsActiveAfterClosingProject
Same way as Stefan:
I could reproduced this bug.
[2bb7bb]: Merge branch 'bug-8388-RemovePic2VtkDependency'
Merged commits:
2014-01-22 14:04:46 Silvio Kolb [4fb9dd]
module dependency was already removed.
deleted commented code that used the removed include file.
New remote branch pushed: bug-8388-RemovePic2VtkDependency